ACS Manufacturing, Inc.
  • Home
  • About Us
    • Capabilities
    • What Makes Us Different
    • Company History
    • Facility
  • Products
    • Acoustical Enclosure
    • Weather Enclosure
    • Oil & Gas Equipment
    • Switch Gear Buildings
    • Fuel Maintenance System
    • Fuel Tanks >
      • UL 142
      • UL 2085
      • Generator Set Base Fuel Tanks
    • Trailers
    • Turbine Exhaust Systems
    • Turbine Ventilation Systems
    • Turbine Enclosure Assemblies
    • Intake Plenum Assemblies
    • Inlet Silencer Assemblies
    • Inlet Evaporative Cooler Systems
    • Inlet Filtration Systems
  • Applications
    • Power Generations
    • Oil & Gas >
      • Oil & Gas Equipment
    • Data Centers
    • Hospitals
    • Waste Water
  • Customer Care
    • SC Customer Care
    • TX Customer Care
  • Contact
  • CAREERS
    • South Carolina Jobs
    • Texas Jobs
  • Portal
    • Web Version
    • Mobile Version
Picture

GENERATOR SET BASE FUEL TANKS
Our secondary containment sub-base fuel tanks for industrial gen-sets are designed, fabricated and tested in accordance with UL-142 standards and labeled per UL-142 specifications. ACS's Series 1800 fuel tanks are UL approved design for tanks measuring up to 48" high x 144" wide x over 480" length with a fuel capacity of up to 18,000 gallons.

 STANDARD CONSTRUCTION
  • Tanks are designed to support the weight of the Gen-Set packaged equipment
  • Both the primary tank and secondary tanks are pressure tested to 3 PSI.
  • Material of construction:
        -Primary tank is constructed of 10 gauge; sides, ends, bottom and baffles
         (baffles separate cold/hot returning fuel).
        -Secondary tank is constructed of 1/4" thick sides, 7 gauge ends, bottom and top.

        -Four(4) lifting lugs, designed to lift the weight of the tank. Lifting lug capacity is UL approved.

STANDARD FEATURES
  • One(1) 2" fuel fill locking manual cap
  • One(1) fuel supply - NPT size determined by engine kw or customer specification
  • One(1) fuel return - NPT size same as fuel supply.
  • Primary tank normal vent cap - Size determined by tank capacity. Vent will be piped to outside and above the enclosure roof, on packaged units.
  • Two(2) emergency pressure relief vents (One(1) Primary, One(1) Secondary) - Size determined by tank wetted surface area. (Calculated based on 100% primary tank).
  • One(1) fuel gauge direct reading indicator gauge.
  • One(1) low level float alarm switch assembly - with 1/2" NPT electrical connection.
  • One(1) secondary tank leak detector float alarm switch assembly - with 1/2" NPT electrical connection.
  • One(1) 1" NPT secondary tank drain - with plug.
  • One(1) electrical stub area - size and location determined by gen-set kw.
  • All connections are labeled for identification.
  • Exterior tank surfaces are cleaned, primed and painted per customer requirements.

OPTIONS
  • High level float alarm switch assembly with 1/2" NPT electrical connection.
  • 1" NPT primary tank over flow connection.
  • 2-6 GPM fuel supply and return motor/pump.
  • 6-10 GPM fuel supply manual pump.
  • 7 1/2 Gallon fuel spill container assembly - mounted inside or outside enclosure.
  • Fuel immersion heater assembly with low fuel shutoff switch.
  • Fuel tank monitoring panel - wired to fuel tank connections.
  • Fuel tank annuciator panel - wired to fuel tank connections.
  • Combination low/high level float switch assembly with 1/2" NPT electrical connection for fuel pump start-up control.
  • UL rated lift lugs capable of lifting the entire package (gen-set, enclosure and tank)

OPTIONAL
  • On heavy weight gen-set packaged assemblies, tanks are placed in a structural I-beam base skid with 4 lifting lugs that are designed to lift the entire gen-set packaged assembly.
  • ACS can fabricate tanks of 304 or 316 L stainless steel material.

OUR PRODUCTS

Acoustical Enclosures
Weather Enclosures
Oil & Gas Equipment
Switch Gear Buildings
Fuel Maintenance System
Fuel Tanks -UL 142 & 2085
Trailers
Turbine Exhaust System
Turbine Ventilation System
Turbine Enclosure Assembly
Intake Plenum Assembly
Inlet Silencer Assembly
Inlet Evaporative Cooler System
Inlet Filtration System

APPLICATIONS

Power Generation
Oil & Gas
Data Centers
Hospitals
Waste Water

OUR COMPANY

Company History
What Makes Us Different
Capabilities
Facilities
Human Resources
Customer Care
Contact Us
JOIN US ON:
DOWNLOAD FILES
COMPANY BROCHURE
 CONTACT US:
903.462.2001 - Corporate Office
864.999.2280 - South Carolina

info@acsmanufacturing.com

SUBMIT RESUME AND APPLICATION TO:
Texas:  txjobs@acsmanufacturing.com
South Carolina:  scjobs@acsmanufacturing.com


ACS MANUFACTURING'S MISSION STATEMENT
​ACS Manufacturing, Inc. is dedicated to customer satisfaction. We are in business to satisfy our customers by delivering products on time, at a competitive price, while meeting the customer needs. Further, we will strive to gain and hold the loyalty and respect of our customers by providing products and services of the highest possible value.

Copyright © 2014 | ACS Manufacturing, Inc. | 903.462.2001 | info@acsmanufacturing.com