top of page

Search Results

5 results found with an empty search

  • TRAILERS

    ACS designs and manufactures the highest quality fuel tank trailers in the power generation industry. The trailers can accommodate gen-sets up to 2000 kw and be furnished with a welded-in or removable fuel tank. STANDARD FEATURES: Single or tandem torsion axles up to 24,000 lbs. with 12 volt all wheel brakes and E-Z lube hubs White Mini-Mod wheels with radial tires to match axle capacity Formed Steel Fenders Tongue mounted tool box with lock -able cover latch Battery powered breakaway switch DOT/ICC lighting with six-pole connector plus and sealed beams for long life Welded on ball hitch or adjustable height pintle/ball hitch with safety chains Adjustable tongue jack stand with sandshoes Painted with industrial enamel paint for corrosion resistance OPTIONAL ACCESSORIES: Hydraulic surge brake Parking brake Chrome wheels Spare tire Bolt on cable box with lock-able cover latch FUEL TANK Single or double wall, 10 gauge construction; with necessary fittings, vents and gauge are standard. Additional accessories can be added.  COMPLETE PACKAGING CAPABILITIES ACS can mount and wire your gen-set and furnish an ACS weatheror acoustical enclosure at our facility to provide a complete packaged ready for shipment .

  • FUEL TANKS

    ACS sets the standard in providing superior and dependable fuel tanks, from UL 142 and UL 2085 to day tanks and sub-base fuel tanks for industrial gen-sets.  ​ Our engineering staff utilizes their knowledge of diesel fuel system state and national codes to ensure that tanks are properly sized, designed and fabricated to meet your specifications.  All tanks undergo a rigorous quality control inspection and are tested in accordance with standards. And ACS takes great pride in making certain that all orders are correctly scheduled to ship in a timely manner and meet requested dates. ADDITIONAL FEATURES: Day Tank Pump & Control System Fuel Filtration Systems OSHA Platform, catwalk, & access steps Heater - Cold Weather Installations Ground Level Fuel Fill Station Offshore paint application Capacities up to 20,000 gallons Packaging with GenSet and Enclosure   Fuel Tank Fill Annunciator UL 142 FUEL TANK Our UL 142 tank features a carbon steel, double wall design specially designed to protect against tank leak or rupture. The outer wall protects the inner wall from environmental damage and creates an additional containment barrier in the unusual event that the inner tank ever ruptures. Sub-Base Fuel Tank Stand Alone Rectangular Stand Alone Cylindrical UL 2085 FUEL TANK ACS is one of the few manufacturers to have a ballistic rating on our tanks. Our UL 2085 has a carbon steel outer shell with 6” of concrete encasing a carbon steel fuel tank. The combination of outer shell and concrete creates a ballistic barrier, a 2-hour fire rating, and impact resistance. Sub-Base Stand Alone Rectangular Stand Alone Cylindrical GENERATOR SET BASE FUEL TANKS Our secondary containment sub-base fuel tanks for industrial gen-sets are designed, fabricated and tested in accordance with UL-142 standards and labeled per UL-142 specifications. ACS's Series 1800 fuel tanks are UL approved design for tanks measuring up to 48" high x 144" wide x over 480" length with a fuel capacity of up to 18,000 gallons. STANDARD CONSTRUCTION: Tanks are designed to support the weight of the Gen-Set packaged equipment Both the primary tank and secondary tanks are pressure tested to 3 PSI. Material of construction:          - Primary tank is constructed of 10 gauge; sides, ends, bottom and baffles           (baffles separate cold/hot returning fuel).          -Secondary tank is constructed of 1/4" thick sides, 7 gauge ends, bottom and top.          -Four(4) lifting lugs, designed to lift the weight of the tank. Lifting lug capacity is UL approved. STANDARD FEATURES: One(1) 2" fuel fill locking manual cap One(1) fuel supply - NPT size determined by engine kw or customer specification One(1) fuel return - NPT size same as fuel supply. Primary tank normal vent cap - Size determined by tank capacity. Vent will be piped to outside and above the enclosure roof, on packaged units. Two(2) emergency pressure relief vents (One(1) Primary, One(1) Secondary) - Size determined by tank wetted surface area. (Calculated based on 100% primary tank). One(1) fuel gauge direct reading indicator gauge. One(1) low level float alarm switch assembly - with 1/2" NPT electrical connection. One(1) secondary tank leak detector float alarm switch assembly - with 1/2" NPT electrical connection. One(1) 1" NPT secondary tank drain - with plug. One(1) electrical stub area - size and location determined by gen-set kw. All connections are labeled for identification. Exterior tank surfaces are cleaned, primed and painted per customer requirements. OPTIONS: High level float alarm switch assembly with 1/2" NPT electrical connection. 1" NPT primary tank over flow connection. 2-6 GPM fuel supply and return motor/pump. 6-10 GPM fuel supply manual pump. 7 1/2 Gallon fuel spill container assembly - mounted inside or outside enclosure. Fuel immersion heater assembly with low fuel shutoff switch. Fuel tank monitoring panel - wired to fuel tank connections. Fuel tank annuciator panel - wired to fuel tank connections. Combination low/high level float switch assembly with 1/2" NPT electrical connection for fuel pump start-up control. UL rated lift lugs capable of lifting the entire package (gen-set, enclosure and tank) OPTIONAL: On heavy weight gen-set packaged assemblies, tanks are placed in a structural I-beam base skid with 4 lifting lugs that are designed to lift the entire gen-set packaged assembly. ACS can fabricate tanks of 304 or 316 L stainless steel material.

  • FUEL MAINTENANCE SYSTEMS

    The Fuel Maintenance System (FMS) is a fully automated, stand-alone, self-contained system designed for tanks of varying sizes. It cleans and reconditions stored fuels, eliminating the problems associated with the water, sludge and other contaminants that develop in fuel storage tanks over time. The system’s automatic cleaning program will provide a constant clean fuel supply that will assure the reliable operation of your emergency power unit whenever it is needed. The FMS is operated by a 6” color touch screen PLC/HMI or a basic LCD PLC controller, will periodically circulate your stored fuel through a series of water removal and particulate filters that remove 99.7% of free water and 99.5% of particulate contaminants. It will keep your stored fuel in clean, like new condition, preventing clogged engine filters, injection system repairs and the need for periodic fuel replacement or tank cleaning due to fuel contamination and the resulting degradation. ​ The system is fully monitored and alarmed for safety.  Alarms can be sounded at the unit or communicated off site via a MODBUS (RS 485) serial and Ethernet TCP/IP connection. Two (2) dry contacts for pump running and common alarm are available for customer use.  The system will alarm and can be shut down automatically for any or all of the following conditions: ​ 1.  Hi-pressure at the primary and final filters, indicating a filter change out is needed 2.  Hi-vacuum at the water separator, indicating the separator needs service. 3.  Hi-water in the separator, indicating the need for it to be drained. 4.  Equipped with an in-cabinet drip tray, a leak detector in the tray will sound an alarm and shut  the system down on detection of any liquid, which may indicate an internal system leak. ADDITIONAL FEATURES UL 508A Labeled Control Panel Push button emergency stop located on the outside of the cabinet (remote mount is optional) 3 Position selector switch, Pump-Hand / Off / Auto Control logic short circuit protection, 1 A / 1-Pole

  • WEATHER ENCLOSURES

    ACS designs and manufactures 14- to 16-gauge Galvanneal weather enclosures for gen-sets, pumps, engines, and compressors. These completely sealed structures are able to withstand 125 mph winds, 42 lbs per square foot roof loads, Zone 2 earthquakes, and are rain resistant to 4” per hour. STANDARD FEATURES: 14-16 gauge wall thickness with internal stiffeners, welds and framing. Full-length base channels and rectangular frame tubing Maximum 24" wide interlocking wall panels with internal welds Welded at all connection points. Steel end caps welded at all open tube ends. Mounting holes in the base channel allow fastening directly to base skid or foundation Maximum static pressure drop less than 0.5 inches of water through the enclosure. Inlet and exiting airflow at each end 36” of clearance at back end of gen-set skid Radiator air duct work/flashing installed before shipping. Exhaust opening with 304 stainless steel weather shield 7” fixed galvanized inlet and discharge weather louvers with ½” birdscreen Four (4) lifting lugs for lifting of the enclosure only Exterior surfaces are cleaned, primed and painted with one coat of epoxy and one coat of polane polyurethane. OPTIONAL FEATURES: Materials of Construction: Aluminum and Stainless Steel Radiator Discharge Elbow Gravity Backdraft Dampers Electrical Package

  • ACOUSTICAL ENCLOSURES

    ACS Acoustical Enclosures (standard and custom) are designed to control noise levels of engine driven sets, compressor, and pump systems.  The performance of a standard enclosure will reduce the equipment's noise level to 85 dBA or less, 3 feet from the enclosure and 5 feet above grade level.  Enclosures can be custom designed to reduce equipment noise to meet virtually any sound level required. ​ ​We also offer upgrade options on construction materials, wind load ratings, seismic ratings, sound attenuation and the ability to add off-shore paint or electrical components. GENERAL ENCLOSURE CONSTRUCTION: Materials of Construction: Materials will be properly selected for the type of environment and service life the unit will require. Normal materials of construction for the walls and roof skin, framing and inner liner include aluminum, stainless steel, galvanneal steel.  As well as other materials required to meet arctic conditions. Skin: Material thickness ranges from 16 gauge to 1/4 plate. Perforated inner liner thickness ranges from 24 gauge. Galvanneal steel is standard. Framing: Structural channels, beams, and tubing consistig of carbon steel, stainless steel or aluminum. Insulation Fill Material: 4 to 8 lbs/cu. ft. density wool, with 4 lbs. beig standard. Protective Cover (between insulation and perforated): 2 mil poly is standard.

bottom of page